Flames are fascinating...to stare into, but they must be under control at all times.
The flames are tamed, the fire extinguished, no sign of hazardous gases. This is ensured by a special jacket and a special interior design. Manufactured according to FRNC Guidelines for halogen-free and flame-retardent cables. It's obligatory for all installations in public buildings.
The SC-MATRIX is a digital multipair or modulation cable; because of the large wire diameter of 0.25 mm2 it is also suitable for installation across distances of more than 130 meters. Due to the paired spiral shielding made of braided copper the SC-MATRIX has excellent protection against interference.
This cable is not suitable for mobile application!
THE ADVANTAGES:
- Halogen-free and flame-retardant according to Test Type C (IEC60332-1 + 60332-3)
- In stock in more than 9 different lengths
- Suitable for long distances due to the large wire diameter of 0.25 mm2
- Digitally suitable due to the 110 Ohm surge impedance
- Numbered and color-coded wire pairs for better identification
THE APPLICATION:
- Application as an audio, modulation and as a AES/EBU-cable
- Permanent installation in public buildings, such as schools, theatres, and discos
- Installation in broadcast studios for the connection of sound systems
- Ground installation
TECHNICAL DATA: |
Construction |
[xx(2LI2Y0,25mm2)DH]CH |
Jacket, diameter |
FRNC (test type C) 20,5 mm |
AWG |
23 |
No. of inner conductors |
16 x 2 x 0,25 mm2 |
Copper strand per conductor |
32 x 0,10 mm |
Conductor insulation |
Foam/skin-PE 1,35 mm |
Shielding |
copper spiral + copper braiding overall shielding |
Shielding factor |
copper-spiral 95 % |
Shielding factor |
Cu-braiding 90 % |
Temperature range |
min. -40 °C |
Temperature range |
max. 85 °C |
Fire load per m |
0,90 kWh |
Weight per 1 m |
570 g |
Jacket color |
dark blue |
Packaging |
per m |
ELECTRICAL DATA: |
Capac. cond./cond. per 1 m |
60 pF |
Capac. cond./shield. per 1 m |
105 pF |
Cond. resistance per 1 km |
< 90 Ohm |
Insulation resist. per 1 km |
> 1 GOhm |
Surge impedance at 1.0 Mhz |
110 Ohm |
Damping per 100 m (20 °C) |
1 MHz: 1,74 dB |
Damping per 100 m (20 °C) |
5 MHz: 7,00 dB |
Damping per 100 m (20 °C) |
10 MHz: 11,30 dB |
Damping per 100 m (20 °C) |
20 MHz: 17,80 dB |
Damping per 100 m (20 °C) |
40 MHz: 29,10 dB |
Damping per 100 m (20 °C) |
60 MHz: 39,10 dB |
Damping per 100 m (20 °C) |
80 MHz: 48,30 dB |
Damping per 100 m (20 °C) |
100 MHz: 56,90 dB |
ORDER DATA: |
Order No. |
100-0302-16 |
|
|